Our range of Sterile Assurance consumables and accessories for your autoclave are imported from suppliers in the EU and ensure simple, continuous and consistent monitoring of every sterilisation cycle to ensure that it complies with each parameter of the sterilisation cycle.

Each product is certified to both ISO and EU standards in accordance with a stringent quality management system so that our customers can rely on them meeting and exceeding their expectations.

We can advise you on the best and most effective monitoring system for your requirements, whether you should use a Helix Test, spore testing, or the right time / temperature indicator to use for your steriliser.


Biological Indicator Spore Test – BT20

Biological Monitoring involves processing a quantity of bacteria spores with a known culture in your autoclave and then placing them in an incubator for 24 hours. The spores will change colour in a positive result and proves the lethality of your sterile process in killing the bacteria.

We can carry out spore testing for you on an annual basis or more regularly as a part of your autoclave validation procedure or alternatively you can purchase the incubator and spore tests and do the testing yourself.

Emulating Indicator Class 6 Self-Adhesive – IT27-3.5SAD

A class 6 chemical indicator is validated at 134C for 3.5 minutes to ensure that every item / tray has been effectively passed through the sterilisation cycle. They specifically measure the time / temperature / steam parameters to give the highest level of proof that sterility has been achieved. These are sold as a box of 100 sticky labels.

Autoclave Tape 24mm – V3504045

Autoclave tape serves a dual purpose in binding a pack shut and in proving that the pack has been exposed to the steam sterilisation process. The tape sticks securely to paper, board, plastic & glass and is coated with a heat sensitive adhesive.

Biological Incubator – IC10/20

The Biological Spores are put into the incubator for 24 hours to check the lethality of your sterile process in killing the bacteria. We also offer Biological testing of your autoclave on an annual basis.

Helix Test – GKE C-S-PM-HL-HCPD-KIT

A Helix Test is designed to be used within your autoclave to test the effectiveness of its air removal and steam penetration. Its designed for use in B class autoclaves and gives a simple easy to read “change colour” pass / fail result. The Helix Test is supplied with 100 strips allowing for 1000 tests.

Emulating Indicator Class 6 – IT28

A class 6 chemical indicator is validated at 134C for 4 minutes to ensure that every item / tray has been effectively passed through the sterilisation cycle. They specifically measure the time / temperature / steam parameters to give the highest level of proof that sterility has been achieved. These are sold as a box of 250 indicator strips.

Labelling System

This is a simple to use dual indicator label & gun that creates a direct link between the sterilisation process and the patient. The pack information is printed and applied after sterilisation and the second label can then be peeled off and reapplied to patient records as evidence of an effective process.

Multi Parameter Indicator Class 4 – V3502038

Multi Parameters Indicators are the simplest, easiest and most economical method of monitoring your steam sterilisation process. The indicator is inserted into every tray and give a clear accurate colour change when processed. These are sold as a box of 500 indicator strips.

TDS Meter

A TDS Meter measures total dissolved solids (TDS) per liter of water and is a common and simple way of measuring water quality. The display gives an instant reading and provides an assurance that your water quality is what it should be.

+ Biological Spore Tests - BT20

Biological Indicator Spore Test – BT20

Biological Monitoring involves processing a quantity of bacteria spores with a known culture in your autoclave and then placing them in an incubator for 24 hours. The spores will change colour in a positive result and proves the lethality of your sterile process in killing the bacteria.

We can carry out spore testing for you on an annual basis or more regularly as a part of your autoclave validation procedure or alternatively you can purchase the incubator and spore tests and do the testing yourself.

+ Emulating Indicator Class 6 Self-Adhesive - IT27-3.5SAD

Emulating Indicator Class 6 Self-Adhesive – IT27-3.5SAD

A class 6 chemical indicator is validated at 134C for 3.5 minutes to ensure that every item / tray has been effectively passed through the sterilisation cycle. They specifically measure the time / temperature / steam parameters to give the highest level of proof that sterility has been achieved. These are sold as a box of 100 sticky labels.

+ Autoclave tape 24mm - V3504045

Autoclave Tape 24mm – V3504045

Autoclave tape serves a dual purpose in binding a pack shut and in proving that the pack has been exposed to the steam sterilisation process. The tape sticks securely to paper, board, plastic & glass and is coated with a heat sensitive adhesive.

+ Biological Incubator IC10/20

Biological Incubator – IC10/20

The Biological Spores are put into the incubator for 24 hours to check the lethality of your sterile process in killing the bacteria. We also offer Biological testing of your autoclave on an annual basis.

+ GKE Helix Test

Helix Test – GKE C-S-PM-HL-HCPD-KIT

A Helix Test is designed to be used within your autoclave to test the effectiveness of its air removal and steam penetration. Its designed for use in B class autoclaves and gives a simple easy to read “change colour” pass / fail result. The Helix Test is supplied with 100 strips allowing for 1000 tests.

+ Emulating Indicator Class 6 - IT28

Emulating Indicator Class 6 – IT28

A class 6 chemical indicator is validated at 134C for 4 minutes to ensure that every item / tray has been effectively passed through the sterilisation cycle. They specifically measure the time / temperature / steam parameters to give the highest level of proof that sterility has been achieved. These are sold as a box of 250 indicator strips.

+ Labelling System

Labelling System

This is a simple to use dual indicator label & gun that creates a direct link between the sterilisation process and the patient. The pack information is printed and applied after sterilisation and the second label can then be peeled off and reapplied to patient records as evidence of an effective process.

+ Multi Parameter Indicator Class 4 - V3502038

Multi Parameter Indicator Class 4 – V3502038

Multi Parameters Indicators are the simplest, easiest and most economical method of monitoring your steam sterilisation process. The indicator is inserted into every tray and give a clear accurate colour change when processed. These are sold as a box of 500 indicator strips.

+ TDS Meter

TDS Meter

A TDS Meter measures total dissolved solids (TDS) per liter of water and is a common and simple way of measuring water quality. The display gives an instant reading and provides an assurance that your water quality is what it should be.